Microwave Level Switch for process temp. up to +200°C for level detection or dry-run protection for liquids and solids - OPTISWITCH 6500
in stock
Ready to ship within 9 business days - free shipping | Details(Purchase and delivery only within Germany and Austria, Belgium, Netherlands and Metropolitan France)
Product characteristics
- Hygienic level switch completly out of stainless steel with LED swichting point indication and transistor output
- Robust stainless steel signal converter housing
- Measure changing mediums with dielectric constant > 1,8
- Insensitive to build up or foam
- Process temperature:
-40...+85°C (short version)
-40...+200°C (extended version with sliding connection)
Application areas
- Main field of aplication: Food and beverage industry as well as pharmaceuticals and cosmetic industry
- Applicable for measuring of liquids like water or beer as well as solids like sugar or meal
- For detection of i.e. mustard, cream and ketchup or for empty tube detection
KROHNE V-Number:
- VGP9011100000
Medium | liquids and solids |
Measuring function | Level, empty tube, (interface) |
Display (switching condition) | LED |
Dielectric constant εr | > 1,8 |
Resolution / Hysteresis | +/- 1mm / 0,04" |
Output | Transistor output, switchable across the polarity of the auxiliary power between full and low level signal |
Breaking capacity | max. 50mA |
Auxiliary power | 12...36V DC; max. 70mA |
Material housing | Stainless steel 1.4301 |
Ambient temperature | -40...+85°C / -40...+185°F |
Ingress protection | IP 67 / NEMA 4X |
Process connection | G 1/2" h, (Sensor length: short:18mm, long: 250mm), long version standard with sliding connection, both are suitable for the hygienic adapter standing on the bottom, seal-free |
Available hygienic adapter | - Hygienic welded sleeve* - Milk pipe connection DN 25 DIN 11851* - Tri Clamp 2" respectively DIN 32676 - ISO 2852* - sliding connection * = certificated according 3A |
Process temperature | -40...+85°C / -40...+185°F (short version) -40...+200°C** / -40...+392°F** (extended Version with sliding connection) ** = max. temperature, depends on the immersion depth, Details behold data sheet |
Pressure range | - max. 40 bar / 580 psi (short Version) - max. 16 bar / 232 psi (long Version) |
Material sensor | Stainless steel 1.4404 / 316L |
Material sensor peak | PEEK, FDA conform |
Electrical cable glands | M16, plastic |
Elektrischer Anschluss
Beschreibung: Schließer (NO) und Öffner (NC)
PNP
M12-Stecker
1: braun; 2: weiss; 3: blau; 4: schwarz
NPN
M12-Stecker
1: braun; 2: weiss; 3: blau; 4: schwarz
Digitalausgang
Abmessungen
G½" Hygieneanschluss, DN38 Hygieneanschluss und G½" hygienische Verschiebemuffe (von links nach rechts)
1. M12x1 Stecker
2. M16x1.5 Kabelverschraubung
3. SW 22
4. G½"
5. PEEK-Fühlerspitze
6. Länge der Verschiebemuffe (entsprechend den Bestelldaten)
7. Sicherheitskette
8. Stutzen für G½" hygienische Verschiebemuffe
Hygienische Prozesseinschweißmuffe mit Sensoranschluss G½ h hygienisch mit Sensoranschluss G½ h hygienisch, aus Edelstahl 1.4404
1. 34 mm / 1,3"
2. G½
3. Ø30 mm / Ø1,2"
Milchrohranschluss DIN 11851 DN 25 mit Überwurfmutter und mit Sensoranschluss G½ h hygienisch, aus Edelstahl 1.4404
1. G½
2. 34 mm / 1,3"
3. 44 mm / 1,7"
Tri Clamp 2", DIN 32676, ISO 2852 - Inkl. EPDM-Dichtung mit Sensoranschluss G½ h hygienisch, metallisches bzw. PEEK-Dichtungssystem
1. SW27
2. G½
3. 34 mm / 1,3"
4. Ø50,5 mm / Ø2"
Betriebsbedingungen für die Verschiebemuffe bei verschiedenen Messstofftemperaturen
Messstofftemperatur im Vergleich zur externen Länge der Verschiebemuffe
a = Messstofftemperatur in [°C] oder [°F]
b = externe Länge der Verschiebemuffe in [mm] oder ["]
1. Tamb= max. 40 °C / 104 °F
2. Tamb= max. 60 °C / 140 °F
3. Tamb= max. 75 °C / 167 °F
4. Tamb= max. 85 °C / 185 °F
Beispiel zur Interpretation der Abbildung:
Eine 250 mm / 9,9" Verschiebemuffe ist mit einer Eintauchlänge von insgesamt 150 mm / 5,9" in einen Tank montiert. Die externe Länge der Verschiebemuffe beträgt daher:
250 - 150 = 100 mm bzw. 9,9 - 5,9 = 4".
Die Messstofftemperatur beträgt maximal 160 °C / 320 °F.
Das Ablesen der X-Achse bei 100 mm / 4" und der Y-Achse bei 160 °C / 320 °F ergibt, dass die Umgebungstemperatur unterhalb von 40 °C / 104 °F liegen muss. Sollte die vom Tank ausgehende Wärme eine höhere Umgebungstemperatur am Gehäuse verursachen, ist eine effizientere Isolierung des Tanks notwendig.
-
Order number: ES41410045
Quantity | Unit price |
---|---|
To 3 | € 238,00* |
From 4 | € 227,00* |
From 11 | € 215,00* |