Microwave level switch for process temp. up to +115°C for level detection or for dry-run protection for liquids and solids - OPTISWITCH 6600
in stock
Ready to ship within 9 business days - free shipping | Details(Purchase and delivery only within Germany and Austria, Belgium, Netherlands and Metropolitan France)
Product characteristics
- Hygienic level switch completly out of stainless steel with LED swichting point indication and transistor output
- Measure changing mediums with dielectric constant > 1,8
- Insensitive to build up or foam
Application areas
- Main field of aplication: Food and beverage industry as well as pharmaceuticals and cosmetic industry
- Applicable for measuring of liquids like water or beer as well as solids like sugar or meal
- For detection of i.e. mustard, cream and ketchup or for empty tube detection
KROHNE V-Number:
- VGPA011100000
Medium | Liquids and solids |
Measuring function | Level, empty tube, (interface) |
Display (swichting condition) | LED |
Dielectric constant εr | > 1,8 |
Resolution / Hysteresis | +/- 1mm / 0,04" |
Output | Transistor output, switchable across the polarity of the auxiliary power between full and low level signal |
Breaking capacity | max. 20mA |
Auxiliary power | 12...30V DC; max. 35mA |
Material housing | Stainless steel 1.4301 |
Ambient temperature | -40...+85°C / -40...+185°F |
Ingress protection | IP 67 / NEMA 4X |
Process connection | G 1/2" h, 15mm, seal free |
Available hygienic adapter | - Hygienic welded sleeve* - Milk pipe connection DN 25 DIN 11851* - Tri Clamp 2" respectively DIN 32676 - ISO 2852* * = certificated according 3A |
Process temperature | -40...+115°C / -40...+239°F (behold separate diagramm on the data sheet) -40...+130°C / -40...266°F < 1h, Tamb < 40°C / 104°F |
Pressure range | - max. 40 bar / 580 psi |
Material sensor | Stainless steel 1.4404 / 316L |
Material sensor peak | PEEK, FDA konform |
Electrical cable glands | Plug M12 |
Elektrischer Anschluss
Beschreibung: Schließer (NO) und Öffner (NC)
PNP
M12-Stecker
1: braun; 2: weiss; 3: blau; 4: schwarz
NPN
M12-Stecker
1: braun; 2: weiss; 3: blau; 4: schwarz
Abmessungen
Hygienische Prozesseinschweißmuffe mit Sensoranschluss G½ h hygienisch mit Sensoranschluss G½ h hygienisch, aus Edelstahl 1.4404
1. 34 mm / 1,3"
2. G½
3. Ø30 mm / Ø1,2"
Milchrohranschluss DIN 11851 DN 25 mit Überwurfmutter und mit Sensoranschluss G½ h hygienisch, aus Edelstahl 1.4404
1. G½
2. 34 mm / 1,3"
3. 44 mm / 1,7"
Tri Clamp 2", DIN 32676, ISO 2852 - Inkl. EPDM-Dichtung mit Sensoranschluss G½ h hygienisch, metallisches bzw. PEEK-Dichtungssystem
1. SW27
2. G½
3. 34 mm / 1,3"
4. Ø50,5 mm / Ø2"
Temperaturgrenzen
Medientemperatur im Vergleich zur Umgebungstemperatur
a = Messstofftemperatur in [°C] oder [°F]
b = Umgebungstemperatur in [°C] oder [°F]
CIP: 130 °C / 266 °F < 1 Stunde (Tamb < 40 °C / 104 °F)
-
Order number: ES41410085
Quantity | Unit price |
---|---|
To 3 | € 201,00* |
From 4 | € 193,00* |
From 11 | € 182,00* |